Dental clinics depend on precise fluid control within steam disinfection devices to achieve reliable sterilization outcomes. The closed magnetic flow valve series we supply forms the core of that precision. The Dental sterilizer NC electromagnetic control valve is a direct-acting unit that remains securely closed until energized, eliminating any chance of unintended fluid release during idle periods. In oral autoclave cycles, the Normally closed magnetic valve for oral steam sterilizer delivers consistent shut-off performance, even as steam temperature and pressure oscillate. Clinics that demand full compliance with B-grade sterilization standards select the B-grade dental disinfection equipment closed solenoid valve which is validated for multi-phase vacuum and steam pulses. To complete the family, the Oral autoclave normally shut electromagnetic fluid valve adopts a balanced poppet design suitable for high-frequency switching in compact benchtop sterilizers. Each variation shares a common architecture that prioritizes patient safety and instrument longevity.
The <产品名字> is engineered to meet the demanding requirements of modern dental practices. Its magnetic core and precision-machined body ensure rapid closure and zero fluid retention during the sterilization cycle. Manufactured in an ISO-certified facility, this closed magnetic flow valve undergoes rigorous pressure and endurance testing to guarantee millions of maintenance-free cycles. The device integrates seamlessly into existing autoclave plumbing systems and supports both distilled water and chemical disinfectant lines. Whether retrofitting an older sterilizer or designing a next-generation unit, the compact footprint and flexible coil orientation simplify installation in space-constrained cabinetry.
| Parameter | Value |
|---|---|
| Valve Type | Normally Closed (NC) Direct-Acting Magnetic Flow Valve |
| Body Material | AISI 316L Stainless Steel, electropolished |
| Seal Material | PTFE (Polytetrafluoroethylene) with FKM backup ring |
| Operating Pressure | 0 to 8 bar (0 – 116 psi) |
| Fluid Temperature Range | 5°C to 185°C (41°F – 365°F) |
| Coil Voltage Options | 24V DC / 110V AC / 220V AC (50/60 Hz) |
| Response Time (Close) | < 15 ms |
| Orifice Diameter | 1.2 mm to 4.5 mm (custom sizes available) |
| Port Connection | G1/8″ or G1/4″ BSPP / NPT thread |
| Ingress Protection | IP67 (dust-tight, immersion resistant) |
| Cycle Life Tested | > 3 million cycles |
| Certifications | CE, RoHS, REACH, ISO 13485 compliant |
The valve handles distilled water, hydrogen peroxide-based disinfectants, and mild alkaline cleaning solutions without degradation. A strainer integrated at the inlet port catches particulates, preventing seat contamination. Mounting that accommodates any orientation is supported by a 360° rotatable coil housing. Pipe fittings should be tightened to 15 Nm torque, and the O-ring seal requires only hand pressure to seat. Wiring is simplified via a DIN 43650A connector with captive screw terminals. For maintenance planning, we recommend inspecting the diaphragm every 12 months under standard clinic usage patterns.